2.3.1 Configuration with profile programming
NOTE
The device can be configured for the specific application using the convenient "Profile
programming" function. This involves presenting the device with a set of printed config‐
uration bar codes. The bar codes can be created using the SOPAS ET configuration
software.
The “Profile programming” function is activated in the default factory settings. After
successfully configuring the device, deactivate this function using SOPAS ET to avoid
any undesired configuration changes and exclude the resultant risks.
The configuration of this function and further documentation can be found on the
Internet after logging on at: supportportal.sick.com/profile-programming-clv
2.4
Hazard warnings and operational safety
To reduce health risks and to avoid dangerous situations, observe the safety notes and
warnings set out in the following sections of this Technical Information.
2.4.1 Laser radiation
The devices uses a red light laser diode operating at the wavelength 655 nm. They
correspond to laser class 2.
CAUTION
Optical radiation: Laser class 2
The human eye is not at risk when briefly exposed to the radiation for up to 0.25
seconds. Exposure to the laser beam for longer periods of time may cause damage to
the retina. The laser radiation is harmless to human skin.
Do not look into the laser beam intentionally.
Never point the laser beam at people's eyes.
If it is not possible to avoid looking directly into the laser beam, e.g., during
commissioning and maintenance work, suitable eye protection must be worn.
Avoid laser beam reflections caused by reflective surfaces. Be particularly careful
during mounting and alignment work.
Do not open the housing. Opening the housing may increase the level of risk.
Current national regulations regarding laser protection must be observed.
Caution – Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure.
It is not possible to entirely rule out temporary disorienting optical effects, particularly
in conditions of dim lighting. Disorienting optical effects may come in the form of
dazzle, flash blindness, afterimages, photosensitive epilepsy, or impairment of color
vision, for example.
Output of laser radiation at the device
The entire viewing window is a laser output aperture.
2 SAFETY INFORMATION
8
T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing 8021479/19ZB/2021-10-29 | SICK
Subject to change without notice

Other manuals for SICK CLV62 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV62 Series and is the answer not in the manual?

SICK CLV62 Series Specifications

General IconGeneral
BrandSICK
ModelCLV62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals