EasyManuals Logo

SICK CLV63 Series User Manual

SICK CLV63 Series
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
Pin Signal Function
17
6.5 Connection diagrams
Standard version, cable, 15-pin male connector
“V
S
“Host”
Aux 1”
“Result 2”
“Result 1”
“CAN”
“Sensor 2”
“Sensor 1”
AUX”
CAN bus
“Result 1”
“Result 2”
PLC
CDB620/ CDM420 !
Connection module 4
“Host”
Aux 1”
RS-232
HOST/PLC
Further data
processing 6
PC
Configuration
Diagnostics 5
Interfaces 2
RS-232/422
“Sensor 2”
“Sensor 1”
“External input 2”
“External input 1”
CMC600
â
á
à
V
S
8
= ß
“External output 2”
“External output 1”
Device 1
9 7
USB
Aux 2”
“USB” (Aux 2) 3
Figure 34: Standard version: Electrical connections on the bar code scanner with connecting
cable, 15-pin male connector, D-Sub-HD
!
Here CDM420-0001 or CDM420-0006
1
Device
2
Interfaces
3
USB not required for CLV62x
4
Connection module
5
Configuration or diagnostics
6
Further data processing
7
External switching outputs
8
Supply voltage V
S
9
External switching inputs
ß
CMC600 parameter memory module is required to be able to use the additional external
switching inputs and outputs of the device (highlighted in gray)
à
Other functions
á
Application-dependent alternative stop reading cycle (e.g., photoelectric sensor) or travel
increment (incremental encoder)
â
Start/Stop reading sensor (e.g., photoelectric sensor)
6 ELECTRICAL INSTALLATION
46
O P E R A T I N G I N S T R U C T I O N S | CLV63x, CLV64x, CLV65x 8019588/129Z/2019-02-07 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK CLV63 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK CLV63 Series and is the answer not in the manual?

SICK CLV63 Series Specifications

General IconGeneral
BrandSICK
ModelCLV63 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals