EasyManua.ls Logo

SICK Lector621 - 13.7.4 Wiring serial host interface RS-232 of the device in CDM420-0001

SICK Lector621
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device
1 CDM420-0001 Host
5
.
.
.
TxD
RxD
RxD
TxD
GND
GND
GND
9
7
34
T/TxD
35
R/RxD
36
GND
6
Shield
RS-232 RS-232
S2
OFFON
110
15
6
11
5
3
Cable 2
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
Figure 76: Wiring data interface RS-232 of the device in the connection module CDM420-0001
1
Device
2
Connecting cable permanently connected with the device (male connector, D-Sub-HD, 15-pin)
3
Connection module: female connector, D-Sub-HD, 15-pin
NOTE
Activate the RS-232 data interface in the device with a configuration tool, e.g. the con‐
figuration software SOPAS ET.
13.7.5 Wiring serial host interface RS-422 of the device in CDM420-0001
Device = Lector621 ECO = V2D621x-xxxxxYx (serial variant, Y = D or E)
Device 1 CDM420-0001 Host
5
.
.
.
TD+
TD‒
RD+
RD‒
RD+
RD‒
TD+
TD‒
GND
GND
GND
8
9
6
7
24
T+
34
T/TxD
25
R+
35
R/RxD
36
GND
6
Shield
RS-422 RS-422
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
OFF
S3
OFF
120 Ω
110
15
6
11
5
3
Cable 2
Figure 77: Wiring data interface RS-422 of the device in the connection module CDM420-0001
13 ANNEX
120
O P E R A T I N G I N S T R U C T I O N S | Lector621 8022502/15NT/2020-02-11 | SICK