Device
1 CDM420-0001 Host
5
.
.
.
TxD
RxD
RxD
TxD
GND
GND
GND
9
7
34
T‒/TxD
35
R‒/RxD
36
GND
6
Shield
RS-232 RS-232
S2
OFFON
110
15
6
11
5
3
Cable 2
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
Figure 76: Wiring data interface RS-232 of the device in the connection module CDM420-0001
1
Device
2
Connecting cable permanently connected with the device (male connector, D-Sub-HD, 15-pin)
3
Connection module: female connector, D-Sub-HD, 15-pin
NOTE
Activate the RS-232 data interface in the device with a configuration tool, e.g. the con‐
figuration software SOPAS ET.
13.7.5 Wiring serial host interface RS-422 of the device in CDM420-0001
Device = Lector621 ECO = V2D621x-xxxxxYx (serial variant, Y = D or E)
Device 1 CDM420-0001 Host
5
.
.
.
TD+
TD‒
RD+
RD‒
RD+
RD‒
TD+
TD‒
GND
GND
GND
8
9
6
7
24
T+
34
T‒/TxD
25
R+
35
R‒/RxD
36
GND
6
Shield
RS-422 RS-422
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
OFF
S3
OFF
120 Ω
110
15
6
11
5
3
Cable 2
Figure 77: Wiring data interface RS-422 of the device in the connection module CDM420-0001
13 ANNEX
120
O P E R A T I N G I N S T R U C T I O N S | Lector621 8022502/15NT/2020-02-11 | SICK
Subject to change without notice