EasyManua.ls Logo

SICK NAV350

SICK NAV350
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning and configuration
52 © SICK AG · Germany · All rights reserved · Subject to change without notice
8013889/ZML0/2017-06-
09
Operating Instructions
NAV350 Laser positioning sensor
Chapter 6
6.3.1 Connect the data interfaces
Connect the PC to the NAV350 using the Ethernet cable (see fig. 28 on page 48)
or
Connect the PC (serial interface) to the NAV350 (see fig. 29 on page 48)
6.3.2 Starting SOPAS ET and opening the scan assistant
1. Start SOPAS ET.
By default SOPAS ET opens the program window with the English user interface.
2. To change the language setting, in the start dialog box click C
ANCEL and using the menu
T
OOLS, OPTIONS change the language for the user interface to GERMAN.
3. If the language setting has been modified, quit SOPAS ET and re-start.
4. In the dialog box, choose the option C
REATE NEW PROJECT and confirm with OK.
5. In the main window in S
CAN ASSISTANT click the CONFIGURATION button.
The S
CAN ASSISTANT dialog box appears.
6.3.3 Configuring the serial connection
1. In the S
CAN ASSISTANT dialog box, under SERIAL CONNECTION, STANDARD PROTOCOL, activate
the A
CTIVATE SERIAL COMMUNICATION checkbox.
2. Click A
DVANCED... button.
3. In C
OLA DIALECT choose the ASCII option.
4. Choose following P
ORT SETTINGS: 8 data bits, even parity, 1 stop bit.
5. Confirm the settings with OK.
The A
DVANCED SCAN SETTINGS dialog box is closed.
6. Confirm the settings in the S
CAN ASSISTANT dialog box with OK.
The S
CAN ASSISTANT dialog box is closed.
6.3.4 Configuring the Ethernet connection
The factory setting for the Ethernet interface of the NAV350 is as follows:
IP address: 192.168.1.10
subnet mask: 255.255.255.0
TCP/ IP port for SOPAS ET: 2111
Configuring with fixed IP address
Important Deactivate all programs on your PC/notebook that access Ethernet or TCP/IP.
1. From the START MENU, click CONTROL PANEL and choose NETWORK CONNECTIONS.
2. Right-click the LOCAL AREA CONNECTION icon, and then choose PROPERTIES.
3. On the GENERAL tab, highlight INTERNET PROTOCOL (TCP/IP), and then click PROPER-
TIES
4. Select USE THE FOLLOWING IP ADDRESS, and enter the following IP address:
192.168.1. x (e.g. 1)
5. Confirm with OK