Product description
36 © SICK AG · Germany · All rights reserved · Subject to change without notice
8013889/ZML0/2017-06-
09
Operating Instructions
NAV350 Laser positioning sensor
Chapter 3
3.10 Planning
3.10.1 System requirements of the NAV350
For commissioning and operating the NAV350, the following are required at the user:
Supply voltage DC 24 V ±15%, generated as per IEC 60364-4-41 (VDE 0100, part 410),
output power minimum 40 W (see section 5.3.1 “Supply voltage” on page 46)
Standard Intel Pentium PC or compatible, at least Pentium III, 500 MHz
RAM: minimum 256 MB, 512 MB recommended
operating system: MS Windows 2000, XP, VISTA or 7
monitor: minimum 256 colours, 65,536 colours recommended;
Screen resolution a
t least 800×600
hard disc: minimum 220 MB free memory
data interface RS232 or Ethernet (see section 5.3.3 “General conditions for the data
interface” on page 47), if necessary RS232 converter, if PC interface and interface on
the NAV350 do not match
3.10.2 Mounting requirements
The NAV350 must be mounted stable.
For the NAV350 the mounting kit part no. 5311055 with mounting material is available.
As an alternative you can use a strong stable mounting bracket that provides adjustable
alignment of the NAV350 in the X- and Y axis. The NAV350 weighs approx. 2.4 kg (5.29 lb).

Table of Contents