NOTE
The product is a programmable device. The respective programmer is therefore respon‐
sible for his/her programming work and the resultant operation of the device. The liabil‐
ity and warranty of SICK AG is limited to the device specification (hardware functionality
and any programming interfaces) according to the agreed conditions. SICK AG will
therefore not be liable, among other things, for any damages resulting from the pro‐
gramming of the product by the customer or third parties.
2.5 Modifications and conversions
NOTICE
Modifications and conversions to the device may result in unforeseeable dangers.
Interrupting or modifying the device or SICK software will invalidate any warranty claims
against SICK AG. This applies in particular to opening the housing, even as part of
mounting and electrical installation.
2.5.1 Exception: temporarily opening the cover on the device
NOTICE
The user may open the housing only in order to obtain temporary access to the USB
interface or the slot for the optional memory card. For this purpose, the corresponding
side cover on the device can be opened temporarily.
In open state, the device does not conform to a specified enclosure rating. The device
must be protected appropriately against moisture and dust.
b
Operate the device only for a short time without closed cover.
NOTE
The USB interface of the device is used in industrial environments only as a service
interface for temporary use (e.g. for configuration, troubleshooting). Permanent use in
real operation of the system as a host interface is not intended.
For further warranty provisions, see the General Terms and Conditions of SICK AG, e.g.
on the delivery note of the device.
2.5.2 Conditions for specified enclosure rating
To ensure compliance with the specified IP65 or IP67 enclosure rating of the device
during operation, the following requirements must be met: If these requirements are
not met, the device does not fulfill any specified enclosure rating.
All variants:
•
The side cover for the USB interface and the microSD card slot must be screwed
tight to the device. Recommended tightening torque for the cover screws: 60 Ncm
±5 Nm.
RFU62x-101xx and RFU62x-105xx (both IP67):
•
The cables plugged into the electrical M12 connections must be screwed tight.
•
Any electrical M12 connections that are not being used must be sealed with pro‐
tective plugs or caps, depending on type. These plugs or caps must be screwed
tight (as delivered).
SAFETY INFORMATION 2
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
11
Subject to change without notice