RFU62x-101xx RFU62x-104xx RFU62x-105xx
PROFIBUS
2)
Via external CDF600-21xx fieldbus module
4)
to
PROFIBUS (RS-485) for data output (read
result).
–
USB
3)
Aux (USB 2.0) for servicing
1)
Digital switching
inputs
2 x physical. Optional 2 additional external logi‐
cal inputs (software-controlled) via a
CMC600
4)
module in the CDB
4)
or CDM con‐
nection module
4)
V
in
= max. 30 V, I
in
= max. 5 mA
Opto-decoupled, reverse polarity protected,
adjustable debounce time
–
Digital switching out‐
puts
2 x physical. Optional 2 additional external logi‐
cal outputs (software-controlled) via a
CMC600
4)
module in the CDB
4)
or CDM con‐
nection module
4)
V
out
= V
S
– 1.5 V, I
out
≤ 100 mA (typical)
Short-circuit protected, temperature protected,
not electrically isolated from the supply voltage
–
Antenna Transmitting/receiving, 1 x internal
Optical indicators 7 x RGB LEDs (status indicator)
5)
at the top front and at the side.
4 x RGB LEDs (process feedback) in the four corners of the antenna
cover. Configurable indicator function with pre-defined color assign‐
ment
6)
.
Acoustic indicator –
Operating elements –
Configuration SOPAS ET configuration software, CoLa commands (telegrams), web
server
7)
, fieldbus controller (PLC) with additional assistance from SICK
function blocks
Programming Application-specific programming using the SICK AppStudio develop‐
ment environment
8)
.
Further information on this is available online at: www.sick.com/
SICK_AppStudio
1)
For example: configuration, diagnostics, transponder access or display of the read results.
2)
Function blocks for various PLC manufacturers are available online at: www.sick.com/RFU62x
3)
USB interface is intended for temporary use only (servicing).
4)
Optional accessories.
5)
RFU620-105xx: “Data” and “CAN” LEDs are non-functional.
6)
For example using the SOPAS ET configuration software.
7)
Function not supported for RFU62x-104xx (serial variant)
8)
This functionality can be enabled with the SDK6U SD card. Available at: www.sick.com
12.3 Mechanics and electronics
Table 26: Technical data for RFU62x: Mechanics/electronics
RFU62x-101xx RFU62x-104xx RFU62x-105xx
Electrical connection 1 x male connector,
M12, 17-pin, A-coded
1 x female connector,
M12, 4-pin, D-coded
1 x female connector,
USB, 5-pin, Micro-B
type
1 x cable, 0.9 m with
male connector, D-
Sub-HD, 15-pin
1 x female connector,
USB, 5-pin, Micro-B
type
1 x female connector,
M12, 8-pin, X-coded
1 x female connector,
USB, 5-pin, Micro-B
type
12 TECHNICAL DATA
84
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK