Device CDB650-204
External output A Signal B Terminal C
2 EXT. OUT 2 24
Functional principle of the external switching outputs
The device outputs the output states of its logical outputs “External output 1” and
“External output 2” via its serial Aux interface. By means of a software-controlled opera‐
tion, the CMC600 automatically adopts the states via the connecting cable and sets
them on its physical digital switching outputs “EXT. 1” and “EXT. OUT 2” in the connec‐
tion module.
Characteristic data of digital switching outputs
Table 60: Characteristic data of the digital switching outputs “External output 1” and “External
output 2”
Switching behavior PNP switching to supply voltage V
S
Default settings in the device: no function, logic: not inverted (active
high)
Properties
•
Short-circuit protected + temperature protected
•
Not electrically isolated from V
S
Electrical values 0 V ≤ V
out
≤ V
S
(V
S
−1.5 V) ≤ V
out
≤ V
S
at I
out
≤ 100 mA
NOTE
Assign the functions for the external digital switching outputs in the device with a con‐
figuration tool, e.g. the configuration software SOPAS ET.
14.7 Connection diagrams of connection module CDM420-0001
NOTE
RFU62x-101xx (Ethernet variant): An adapter cable (female connector, M12, 17-pin, A-
coded / male connector, D-Sub-HD, 15-pin) is required to connect the device
14.7.1 Wiring overview of the CDM420-0001
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant), 1 switching
input used
ANNEX 14
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
119
Subject to change without notice