EasyManua.ls Logo

SICK RFU62 Series

SICK RFU62 Series
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RFU62x-104xx (serial variant, IP65):
The D-Sub male connector of the connecting cable must be screwed tight with the
contacted female connector.
If an extension cable is used, a corresponding rubber seal (SICK accessory) must
be fitted between the two D-Sub plug connectors. The plug connectors are
screwed together. You can find a suitable IP65 rubber seal online at:
www.sick.com/RFU62x
The same also applies to the EMC requirement (ESD) according to CE.
NOTICE
The device can, if necessary, be operated for a short time without the side cover to per‐
form the following tasks:
Inserting or removing the optional memory card
Temporary use of the USB interface as a servicing interface
During this time, protect the device against moisture and dust.
2.6 Requirements for skilled persons and operating personnel
WARNING
Risk of injury due to insufficient training.
Improper handling of the device may result in considerable personal injury and material
damage.
All work must only ever be carried out by the stipulated persons.
The operating instructions state the following qualification requirements for the various
areas of work:
Instructed personnel have been briefed by the operator about the tasks assigned
to them and about potential dangers arising from improper action.
Skilled personnel have the specialist training, skills, and experience, as well as
knowledge of the relevant regulations, to be able to perform tasks delegated to
them and to detect and avoid any potential dangers independently.
Electricians have the specialist training, skills, and experience, as well as knowl‐
edge of the relevant standards and provisions to be able to carry out work on elec‐
trical systems and to detect and avoid any potential dangers independently. In Ger‐
many, electricians must meet the specifications of the BGV A3 Work Safety Regu‐
lations (e.g. Master Electrician). Other relevant regulations applicable in other
countries must be observed.
The following qualifications are required for various activities:
Table 1: Activities and technical requirements
Activities Qualification
Mounting, maintenance
Basic practical technical training
Knowledge of the current safety regulations in the workplace
Electrical installation,
device replacement
Practical electrical training
Knowledge of current electrical safety regulations
Knowledge of the operation and control of the devices in their
particular application
2 SAFETY INFORMATION
12
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice

Table of Contents