RFU63x-131xx
Vibration resistance EN 60068-2-6:2008-02
Shock resistance EN 60068-2-27:2009-05
Ambient operating temper‐
ature
–25 °C (–30 °C ) ... +60 °C
Storage temperature –30 °C ... +70 °C
Permissible relative
humidity
0% ... 90%, non-condensing
1)
For Firmware Version V2.02
Table 29: Technical data for RFU63x-041xx: Ambient data
RFU63x-041xx
Electromagnetic compati‐
bility (EMC)
EN 301489-3, EN 50121-4:2017
Vibration resistance EN 60068-2-64:2008-02
Shock resistance EN 60068-2-27:2009-05
Ambient operating temper‐
ature
–25 °C (–30 °C
1)
) ... +60 °C
Storage temperature –30 °C ... +70 °C
Permissible relative
humidity
0% ... 90%, non-condensing
Standards EN 50125-3:2003 (railway applications)
1)
For Firmware Version V2.02
12.2 Technical data RFU65x
12.2.1 Features
Table 30: Technical data for RFU65x: Features
RFU65x-101xx
Version
(Working area)
Long range
Product category RFID read/write device (UHF) with internal antenna
Frequency band UHF (860 MHz ... 960 MHz)
Radio equipment approval
(Regional assignment)
Type-dependent. See type-specific online data sheet at:
www.sick.com/RFU65x
Carrier frequency
Transmission output power
RFID standard (air inter‐
face)
EPCglobal UHF Class 1 Generation 2, ISO/IEC 18000-6C
Labeling in type code: RFU6x0-xxxxx
Modulation PR-ASK, DSB-ASK
Connection type Ethernet
MTBF 25 years
1)
Scanning range ≤ 10 m
2)
TECHNICAL DATA 12
8014335/ZTL9/2018-10-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
93