RFU65x-101xx
Antenna Internal antenna
Transmitting power adjustable
Circularly polarized
Axis behavior typically 2 dB
Aperture angle vertical 80° / horizontal 55°
Front-to-back ratio, > 15 dB typical
Service functions Optional, automated saving of parameter data (parameter cloning)
outside the device memory:
Using insertable microSD memory card
3)
in the device
Using parameter cloning module CMC600
3)
in the CDB
3)
or
CDM connection module
3)
Externally in CDF fieldbus module
3)
Clock Network time protocol (NTP), no internal clock
Conformities Type-dependent. See type-specific online data sheet at:
www.sick.com/RFU65x
Certificates Type-dependent. See “Downloads” section online at:
www.sick.com/RFU65x
UL: RFU650-10101 (USA and Canada)
4)
1)
Continuous operation at an ambient operating temperature of +50 °C.
2)
Depending on transponder used and ambient conditions
3)
Optional accessories.
4)
UL-certified if the type label contains the UL logo and the UL conditions are met during device operation.
For further information, see "Certification according to UL61010-1", page 98.
12.2.2 Interfaces
Table 31: Technical data for RFU65x: Interfaces
RFU65x-101xx
Ethernet Host for data output (read result)
Aux for service
1)
Protocol: TCP/IP
Data transmission rate 10/100 Mbit/s
Supported services and protocols (e.g. DHCP, HTTP/HTTPS ...), see
type-specific online data sheet at: www.sick.com/RFU65x
PROFINET
2)
PROFINET single port
PROFINET dual port: Via external fieldbus module CDF600-22xx
4)
to PROFINET (2-port Ethernet) for data output (read result)
Data transmission rate 10/100 Mbit/s
EtherNet/IP Data transmission rate 10/100 Mbit/s
EtherCAT®
2)
Via external fieldbus module CDF600-0300
4)
(gateway mode) to
EtherCAT® (Ethernet) for data output (read result)
Serial RS-232, RS-422/485
Host for data output (read result)
Aux (only RS-232) for service
1)
Data transmission rate: 0.3 kBd ... 115.2 kBd, Aux: 57.6 kBd
CAN Host, data transmission rate: 20 kBit/s ... 1 MBit/s.
Bus length depends on data transmission rate and length of
cable. Typical: 250 m at 250 kBit/s and wire cross-section
0.34 mm
2
Protocols:
CSN (SICK CAN sensor network)
CANopen®
12 TECHNICAL DATA
94