Inductive load
NOTE
Provide an arc-suppression circuit at the digital switching output if an inductive load is
present.
b
Attach a freewheeling diode directly to the load for this purpose.
Table 72: Assignment of placeholders to digital switching outputs
Device CDM420-0001
External output A Signal B Terminal C
1 Aux Out 1 40
2 Aux Out 2 30
Functional principle of the external switching outputs
The device outputs the output states of its logical outputs “External output 1” and
“External output 2” via its serial Aux interface. By means of a software-controlled opera‐
tion, the CMC600 automatically adopts the states via the connecting cable and sets
them on its physical digital switching outputs “Aux Out 1” and “Aux Out 2” in the con‐
nection module
Characteristic data of digital switching outputs
Table 73: Characteristic data of the digital switching outputs “External output 1” and “External
output 2”
Switching behavior PNP switching to supply voltage V
S
.
Default settings in the device: no function, logic: not inverted (active
high)
Properties
Short-circuit protected + temperature protected
Not electrically isolated from V
S
Electrical values 0 V ≤ V
out
≤ V
S
(V
S
− 1.5 V) ≤ V
out
≤ V
S
at I
out
≤ 100 mA
NOTE
Assign the functions for the external digital switching outputs in the device with a con‐
figuration tool, e.g. the configuration software SOPAS ET.
14.8 Connection diagrams of connection module CDM420-0006
NOTE
RFU62x-101xx (Ethernet variant): An adapter cable (female connector, M12, 17-pin, A-
coded / male connector, D-Sub-HD, 15-pin) is required to connect the device
14.8.1 Wiring overview of the CDM420-0006
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant)
14 ANNEX
132
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice