Connection mod‐
ule
Digital switching inputs Reference
CMD420-0001 “Sensor 1”
“Sensor 2”
see "Wiring digital switching inputs
“Sensor 1” and “Sensor 2” of the
device in the CDM420-0001",
page 126
External input 1 (“Aux In 1”)
External input 2 (“Aux In 2”)
see "Wiring digital switching inputs
“External input 1” and “External
input 2” of the device in the
CDM420-0001", page 128
CMD420-0006 “Sensor 1”
“Sensor 2”
see "Wiring digital switching inputs
“Sensor 1” and “Sensor 2” of the
device in the CDM420-0006",
page 139
External input 1 (“Aux In 1”)
External input 2 (“Aux In 2”)
see "Wiring digital switching inputs
“External input 1” and “External
input 2” of the device in the
CDM420-0006", page 141
6.11 Wiring the digital switching outputs (RFU62x-101xx/RFU62x-104xx)
Physical switching outputs on the device
The two physical digital switching outputs “Result 1” and “Result 2” are used to signal
events in the read operation. Different functions can be assigned to them indepen‐
dently of each other for this purpose. If the assigned event occurs, then the correspond‐
ing switching output becomes live after the end of the read cycle for the selected pulse
duration, for example (default).
RFU62x-101xx:
The full complement of digital switching outputs is available in each case:
•
at the male connector of the device (M12, 17-pin, A-coded)
•
at the adapter cable (female connector, M12, 17-pin, A-coded/male connector, D-
Sub-HD, 15-pin)
•
at the open end of the adapter cable (female connector, M12, 17-pin, A-coded /
open end)
RFU620-104xx:
The digital switching outputs are located at the 15-pin D-Sub-HD male connector of the
connecting cable.
NOTE
The RFU62x-105xx (PoE variant) does not have any digital switching outputs.
V
out
3
4
Switching output of device 1
!
"
Signal 2
GND
Figure 34: Wiring a digital switching output
ELECTRICAL INSTALLATION
6
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
63