NOTE
Assign the functions for the digital switching inputs in the device with a configuration
tool, e.g. the configuration software SOPAS ET.
14.7.8 Wiring digital switching inputs “External input 1” and “External input 2” of the device in the
CDM420-0001
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant)
Device 4
CDM420-0001
PNP sensor 7
V
S
GND
3.32 K
6.64 K
V
in
Out
GND
S6
CMC600 3
Aux
(RS-232)
ON
OFF
S6 : SGND
No
YES
S8 : CMC
17
SGND
8
Shield
39
+24 V*
A
Aux In B
+24V*
“External
input C” 5
SensGND
Trigger sensor 1
8
E.g. photo-electric
switch 6
2
Figure 75: Trigger sensor supplied with power by connection module CDM420-0001
1
Trigger sensor, e.g. for read cycle generation
2
Input voltage V
in
3
The optional parameter cloning module CMC600 is required in the connection module in order to be able to use the
additional external digital switching inputs and outputs of the device
4
Device
5
Logical “External input” in the device
6
e.g. photoelectric sensor
7
PNP sensor
8
Supply voltage V
S
CDM420-0001
PNP sensor 4
V
S
GND
Out
GND
S6
V
S ext
V
in
CMC600
No
YES
S8 : CMC
ON
OFF
S6 : SGND
17
SGND
8
Shield
39
+24 V*
A
Aux In B
+24V*
SensGND
Trigger sensor 1
5
2
3
CDM420-0001
V
in
GND
S6
CMC600
ON
OFF
S6 : SGND
No
YES
S8 : CMC
17
SGND
8
Shield
39
+24 V*
A
Aux In B
+24V*
SensGND
3
1
V
S ext
GND
A
17
2
2
Figure 76: Left: Trigger sensor connected potential-free and supplied with power externally. Right: Alternatively switch,
!
sup‐
plied with power by connection module CDM420-0001 or
"
connected potential-free and supplied with power externally.
Switch setting S3 then as in left figure.
14 ANNEX
128
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK