RFU62x-101xx RFU62x-104xx RFU62x-105xx
Certificates Type-dependent. See the “Downloads” section online at:
www.sick.com/RFU62x
1)
Continuous operation at an ambient operating temperature of +50 °C.
2)
Permissible ambient operating temperature range, see "Ambient data", page 85.
3)
Depends on the transponder used and the ambient conditions.
4)
Optional accessories.
5)
Function not supported for RFU62x-105xx.
6)
UL-certified if the type label contains the UL logo and the UL conditions are met during device operation.
For further information, see "Certification according to UL61010-1", page 88.
12.2 Interfaces
Table 25: Technical data for RFU62x: Interfaces
RFU62x-101xx RFU62x-104xx RFU62x-105xx
Ethernet Host for data output
(read result)
Aux for servicing
1)
.
Data transmission
rate: 10/100 MBit/s.
Protocol: TCP/IP.
For the supported ser‐
vices and protocols
(e.g. DHCP, HTTP/
HTTPS ...), see the
type-specific online
data sheet at:
www.sick.com/
RFU62x.
Host for data output
(read result).
Aux for servicing
1)
.
Data transmission
rate: 10/100 MBit/s.
Protocol: TCP/IP.
For the supported ser‐
vices and protocols
(e.g. DHCP, HTTP/
HTTPS ...), see the
type-specific online
data sheet at:
www.sick.com/
RFU62x.
Power over Ethernet
(PoE).
PROFINET
2)
PROFINET single port.
PROFINET dual port:
Via external
CDF600-22xx fieldbus
module
4)
to PROFINET
(2-port-Ethernet) for
data output (read
result).
Data transmission
rate: 10/100 MBit/s
PROFINET single port
or dual port: Via exter‐
nal CDF600-22xx
fieldbus module
4)
to
PROFINET (2-port-Eth‐
ernet) for data output
(read result).
Data transmission
rate: 10/100 MBit/s
PROFINET single port
for data output (read
result).
Data transmission
rate: 10/100 MBit/s
EtherNet/IP Data transmission
rate: 10/100 MBit/s
Data transmission
rate: 10/100 MBit/s
Serial RS-232, RS-422/485
Host for data output (read result)
Aux (RS-232 only) for servicing
1)
Data transmission rate: 0.3 kBd ... 115.2 kBd,
Aux: 57.6 kBd
CAN Host, data transmission rate: 20 kBit/s ...
1 MBit/s.
Bus length depends on data transmission rate
and cable length. Typically: 250 m at
250 kBit/s and wire cross-section
0.34 mm
2
.
Protocols:
CSN (SICK CAN sensor network)
CANopen®
TECHNICAL DATA 12
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
83
Subject to change without notice

Table of Contents

Other manuals for SICK RFU62 Series

Related product manuals