6.4.3 RFU620-105 xx (PoE version)
6.4.3.1 “PoE” connection
Figure 25: Female connector, M12, 8-pin, X-coded
Table 12: Pin assignment of the “PoE” connection
Pin Signal Function
1 TD+ Sender+
2 TD– Sender–
3 RD+ Receiver+
4 RD– Receiver–
5 PoE– Supply voltage-
6 PoE– Supply voltage-
7 PoE+ Supply voltage+
8 PoE+ Supply voltage+
6.5 Instructions for electrical installation when the ambient temperature can fall below
0 °C
NOTE
For mounting instructions, see "Instructions for mounting the device when the ambient
temperature can fall below 0 °C", page 28
All device variants can also be operated at low ambient temperatures. For details, see
"Technical data", page 82
6.5.1 Prerequisites
•
Required supply voltage: see "Supply voltage", page 57
•
Use SICK standard cables for the specified ambient temperature range, see
°
www.sick.com/RFU62x
•
Do not operate the device at ambient temperatures below 0 °C when mounting or
connection work is being carried out.
•
Only carry out connection work at ambient temperatures between 0 °C and
+50 °C. Secure the connecting cables.
•
The side cover for the USB interface and the microSD card slot must be screwed
tight to the device.
•
RFU62x-101xx and RFU62x-105xx: All cables connected to the device must be
clamped. Unused M12 electrical connections must be fitted with screw-on protec‐
tive caps (for male connectors) or sealed with plugs (for female connectors) as
supplied.
•
RFU62x-104xx: The male connector of the connecting cable must be secured.
•
When operating the device at the lower limit of the permissible ambient tempera‐
ture range (see "Technical data", page 82), do not expose the device to strong air
flows (e.g. ventilation system, wind).