12 Technical data
NOTE
The relevant online data sheet for your product, including technical data, dimensional
drawing, and connection diagrams can be downloaded, saved, and printed from the
Internet:
•
www.sick.com/RFU62x
These operating instructions provides additional technical data if required.
12.1 Features
Table 24: Technical data for RFU62x: features
RFU62x-101xx RFU62x-104xx RFU62x-105xx
Version
(Working area)
Mid range
Product category RFID read/write device (UHF) with internal antenna
Frequency band UHF (860 MHz ... 960 MHz)
Radio equipment
approval
(Region assignment)
Type-dependent. The type-specific data sheets are available online at:
www.sick.com/RFU62x
Carrier frequency
Transmission output
power
RFID standard (air
interface)
EPCglobal UHF Class 1 Generation 2, ISO/IEC 18000-6 C
Designation in the type code: RFU6x0-xxxxx
Modulation PR-ASK
Connection type Ethernet Serial (cable) PoE
MTBF 23 years
1)
Heater (integrated) Yes
2)
No
2)
No
2)
Scanning range ≤ 2 m
3)
Antenna Internal antenna
•
Adjustable transmitting power
•
Circularly polarized
•
Axis behavior: typically 2 dB (ETSI), 3 dB (FCC)
•
Aperture angle: 100°
•
Front-to-back ratio: typically > 7 dB
Service functions Optional, semi-automatic backup of the configuration data (parameter
cloning) outside the device memory:
•
By inserting a microSD memory card
4)
into the device
•
Externally via the CMC600 parameter cloning module
4)5)
in the
CDB
4)5)
or CDM connection module
4)5)
•
Externally via the CDF fieldbus module
4)5)
Clock Network time protocol (NTP), no internal clock
Conformities Type-dependent. The type-specific data sheets are available online at:
www.sick.com/RFU62x
UL: RFU620-10101 (USA and Canada)
6)
12 TECHNICAL DATA
82
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice