Characteristic data of digital switching outputs
Table 71: Characteristic data of the digital switching outputs “Result 1” and “Result 2”
Switching behavior PNP switching to supply voltage V
S
Default settings in the device: no function, logic: not inverted (active
high)
Properties
Short-circuit protected + temperature protected
Not electrically isolated from V
S
Electrical values 0 V ≤ V
out
≤ V
S
(V
S
−1.5 V) ≤ V
out
≤ V
S
for I
out
≤ 100 mA
NOTE
Assign the functions for the digital switching outputs in the device with a configuration
tool, e.g. the configuration software SOPAS ET.
14.7.10 Wiring digital switching outputs “External output 1” and “External output 2” of the device in the
CDM420-0001
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant)
Load (e.g. PLC) 4
GND
For inductive load: 6
V
out
Device 1
Aux
(RS-232)
CDM420-0001
CMC600 3
+24 V* (V
S
)
CAux Out B
36
GND
6
Shield
“External
output A2
5
Figure 78: Wiring external digital switching outputs “Aux Out 1” and “Aux Out 2” of the device in the connection module
CDM420-0001
1
Device
2
Logical “External output” in the device
3
The optional parameter cloning module CMC600 is required in the connection module in order to be able to use the
additional external digital switching inputs and outputs of the device
4
Load (e.g. PLC)
5
Output voltage V
out
6
With inductive load: see note
ANNEX 14
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
131
Subject to change without notice