Device 1
CDM420-0001
Load (e.g. PLC) 5
C
5
.
.
.
E
Result D
13
GND
5
Shield
+24 V* (V
S
)
V
S
GND
V
out
Result A
GND
B
1
2
1
For inductive load: 7
6
2
3
4
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
9 8
110
15
6
11
5
Figure 77: Wiring digital switching outputs “Result 1” and “Result 2” of the device in the connection module CDM420-0001
1
Device
2
Supply voltage V
S
3
RFU62x-104xx (serial variant): connecting cable permanently connected with the device (male connector, D-Sub-HD,
15-pin)
4
RFU62x-101xx (Ethernet variant): adapter cable (female connector, M12, 17-pin, A-coded / male connector, D-Sub-HD,
15-pin)
5
Load (e.g. PLC)
6
Output voltage V
out
7
With inductive load: see note
8
Connection module: female connector, D-Sub-HD, 15-pin
9
RFU62x-101xx (Ethernet variant): male connector, M12, 17-pin, A-coded
Inductive load
NOTE
Provide an arc-suppression circuit at the digital switching output if an inductive load is
present.
b
Attach a freewheeling diode directly to the load for this purpose.
Table 70: Assignment of placeholders to digital switching outputs
Device CDM420-0001
Output A Pin B Pin C Signal D Terminal E
Result 1 13 12 Result 1 14
Result 2 14 13 Result 2 15
14 ANNEX
130
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice