EasyManua.ls Logo

SICK RFU62 Series - Page 243

SICK RFU62 Series
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RFU65x-101xx
PROFIBUS
2)
Via external fieldbus module CDF600-21xx
4)
to PROFIBUS
(RS-485) for data output (read result)
USB
3)
Aux (USB 2.0) for service
1)
Digital switching inputs 2 x physical. Optional 2 x additional external logical inputs (soft‐
ware-controlled) via module CMC600
4)
in the CDB
4)
or CDM con‐
nection module
4)
V
in
= max. 30 V, I
in
= max. 5 mA
Opto-decoupled, reverse polarity protected, adjustable debounce
time
Digital switching outputs 2 x physical. Optional 2 x additional external logical outputs (soft‐
ware-controlled) via module CMC600
4)
in the CDB
4)
or CDM con‐
nection module
4)
V
out
= V
S
– 1.5 V, I
out
≤ 100 mA (typical)
Short-circuit protected, temperature protected, not electrically iso‐
lated from the supply voltage
Antenna Sending/Receiving
1 x internal
Optical indicators 7 x RGB LEDs (status indicators) on front top
1 x RGB LED (process feedback) in front center Display function
can be set with pre-defined color assignment
5)
.
Acoustic indicator Beeper (buzzer), can be deactivated
Function for event signaling and volume adjustable
5)
Operating elements 2 x pushbuttons (select and start/stop functions)
Configuration SOPAS ET configuration software, CoLa commands (telegrams),
web server, fieldbus controller (PLC) with additional support by
SICK function blocks
Programming Application-specific programming with SICK AppStudio
6)
develop‐
ment environment.
You can find further information on the Internet at:
www.sick.com/SICK_AppStudio
1)
For example: Configuration, diagnosis, transponder access or display of the read results.
2)
Function blocks for various PLC manufacturers are available online at: www.sick.com/RFU65x.
3)
USB interface only for temporary use (service)
4)
Optional accessories.
5)
e.g. with SOPAS ET configuration software.
6)
Functions can be enabled with the SDK6U SD card. Available at: www.sick.com.
12.2.3 Mechanics and electronics
Table 32: Technical data for RFU65x: Mechanics/electronics
RFU65x-101xx
Electrical connection 1 x male connector, M12, 17-pin, A-coded
1 x female connector, M12, 4-pin, D-coded
1 female connector, USB, 5-pin, Micro B type
Supply voltage V
S
SELV in accordance with currently applicable standard EN
60950-1.
DC 18 V ... 30 V
1)
2)
DC 12 ... 30 V optional
3)
UL-certified devices require a supply voltage in accordance with
SELV - LPS according to UL/IEC/EN60950-1 or class 2 according
to NEC, UL1310.
Power consumption Operation: 20 W typical
4)
Maximum 26 W
5)
Standby: 6 W typical
TECHNICAL DATA 12
8014335/ZTL9/2018-10-14 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x
95
Subject to change without notice

Table of Contents

Other manuals for SICK RFU62 Series

Related product manuals