EasyManua.ls Logo

SICK RFU62 Series - Page 137

SICK RFU62 Series
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RD+/TD+
RD‒/TD‒
RD+/TD+
RD‒/TD‒
GND
Shield 5
Device 1 CDM420-0006 Host
5
.
.
.
TD+
TD‒
RD+
RD‒
GND
GND
GND
11
12
1
5 8
9
6
7
6
24
T+
34
T/TxD
25
R+
35
R/RxD
36
GND
6
Shield
RS-485
RS-485
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
ON
S3
OFF
120 Ω
- RS-485 network: 4
2
3
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
110
15
6
11
5
7 6
Figure 83: Wiring data interface RS-485 of the device in the connection module CDM420-0006
1
Device
2
RFU62x-104xx (serial variant): connecting cable permanently connected with the device (male connector, D-Sub-HD,
15-pin)
3
RFU62x-101xx (Ethernet variant): adapter cable (male connector, D-Sub-HD, 15-pin / female connector, M12, 17-pin, A-
coded)
4
RS-485 network
5
Shielding
6
Connection module: female connector, D-Sub-HD, 15-pin
7
RFU62x-101xx (Ethernet variant): male connector, M12, 17-pin, A-coded
Function of switch S3
Table 76: Switch S3: Term 422
Switch setting Function
ON Terminates the device. Required if the device is located at the end of
the RS-485 bus cable.
OFF No termination
NOTE
User of the RS-485 data interface:
The relevant interface drivers for the device comply with the standard in accor‐
dance with RS-422 and RS-485.
This operating mode is only permitted if all connected devices use a correspond‐
ing RS-485 protocol.
This configuration is not permitted when using the standard data output and pro‐
tocol of the device. In case of doubt, contact SICK Service.
Activate the RS-485 data interface (“Bus” option) in the device using a configura‐
tion tool, e.g. the SOPAS ET configuration software.
14.8.6 Wiring the CAN interface in the CDM420-0006
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant)
ANNEX 14
8015930/ZTM0/2018-11-06 | SICK O P E R A T I N G I N S T R U C T I O N S | RFU62x
137
Subject to change without notice

Table of Contents

Other manuals for SICK RFU62 Series

Related product manuals