Characteristic data of digital switching inputs
Table 82: Characteristic data of the digital switching inputs “External input 1” and “External
input 2”
Switching behavior Power to the input starts the assigned function, e.g. start read cycle.
Default setting in the device: logic not inverted (active high), debounce
time 10 ms
Properties
Opto-decoupled, reverse polarity protected
Can be wired with PNP output of a trigger sensor
Electrical values Low: V
in
≤ 2 V; I
in
≤ 0.3 mA
High: 6 V ≤ V
in
≤ 30 V; 0.7 mA ≤ I
in
≤ 5 mA
NOTE
Assign the functions for the external digital switching inputs in the device with a config‐
uration tool, e.g. the configuration software SOPAS ET.
14.8.9 Wiring digital switching outputs “Result 1” and “Result 2” of the device in CDM420-0006
Device = RFU62x-104xx (serial variant), RFU62x-101xx (Ethernet variant)
Device 1
CDM420-0006
Load (e.g. PLC) 5
C
5
.
.
.
E
Result D
13
GND
5
Shield
+24 V* (V
S
)
V
S
GND
V
out
Result A
GND
B
1
2
1
For inductive load: 7
6
2
3
4
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
9 8
110
15
6
11
5
Figure 89: Wiring digital switching outputs “Result 1” and “Result 2” of the device in the connection module CDM420-0006
1
Device
2
Supply voltage V
S
3
RFU62x-104xx (serial variant): connecting cable permanently connected with the device (male connector, D-Sub-HD,
15-pin)
4
RFU62x-101xx (Ethernet variant): adapter cable (female connector, M12, 17-pin, A-coded / male connector, D-Sub-HD,
15-pin)
5
Load (e.g. PLC)
6
Output voltage V
out
7
With inductive load: see note
8
Connection module: female connector, D-Sub-HD, 15-pin
9
RFU62x-101xx (Ethernet variant): male connector, M12, 17-pin, A-coded
ANNEX 14