Position Description Characteristic
6 Device type 0: Base type (EPCglobal UHF Class 1 Gen‐
eration 2, ISO/IEC 18000-6C)
7 Internal antenna 0: No internal antenna
1: With internal antenna, circularly polar‐
ized
8 Connections for external antennas 0: No connection
3: Three connections
4: Four connections
9 Electrical connections 1: 1 x male connector, M12, 17-pin, A-
coded; 1 x female connector, M12, 4-pin,
D-coded
4: Cable with male connector, D-Sub-HD,
15-pin
5: 1 x female connector, M12, 8-pin, X-
coded
10 ... 11 Country-specific radio equipment
approval
00: Europe ...
Type-dependent, see type-specific online
data sheet at:
•
www.sick.com/RFU62x
NOTE
Not all combinations are possible according to the type code. The available device vari‐
ants can be found online at:
•
www.sick.com/RFU62x
3.1.2.1 Device variants
The RFU62x product family consists of 3 variant lines:
•
RFU62x-101xx (Ethernet variant)
•
RFU62x-104xx (serial variant)
•
RFU62x-105xx (PoE variant)
The variant lines differ with respect to the following features:
Table 2: Differences between the variant lines
Feature RFU62x-101xx RFU62x-104xx RFU62x-105xx
Electrical Interfaces
•
Power
•
Serial Data
1)
•
CAN
•
2 digital switching
inputs
•
2 digital switching
outputs
•
Ethernet
•
USB
2)
•
Power
•
Serial Data
1)
•
CAN
•
2 digital switching
inputs
•
2 digital switching
outputs
•
USB
2)
•
Power
•
Ethernet
•
USB
2)
Supply voltage DC 10 V... 30 V
DC 20 ... 30 V
3)
DC 10 V... 30 V DC 48/57 V
Type of electrical con‐
nections
•
1 x male connec‐
tor, M12, 17-pin, A-
coded
•
1 x female connec‐
tor, M12, 4-pin, D-
coded
•
0.9 m cable with 1
x male connector,
D-Sub-HD, 15-pin
•
1 x female connec‐
tor, M12, 8-pin, X-
coded
Enclosure rating IP67 IP65 IP67
3 PRODUCT DESCRIPTION
16
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice