Position Description Characteristic
6 Device type 0: Base type (EPCglobal UHF Class 1 Gen‐
eration 2, ISO/IEC 18000-6C)
7 Internal antenna 0: No internal antenna
1: With internal antenna, circularly polar‐
ized
8 Connections for external antennas 0: No connection
3: Three connections
4: Four connections
9 Electrical connections 1: 1 x male connector, M12, 17-pin, A-
coded; 1 x female connector, M12, 4-pin,
D-coded
4: Cable with male connector, D-Sub-HD,
15-pin
5: 1 x female connector, M12, 8-pin, X-
coded
10 ... 11 Country-specific radio equipment
approval
00: Europe ...
Type-dependent, see type-specific online
data sheet at:
www.sick.com/RFU63x
www.sick.com/RFU65x
NOTE
Not all combinations are possible according to the type code. The available device vari‐
ants can be found online at:
www.sick.com/RFU63x
www.sick.com/RFU65x
3.1.2.1 Device variants
RFU63x
The RFU63x product family consists of 2 variant lines:
RFU63x-131xx (variant with internal antenna)
RFU63x-041xx (variant without internal antenna)
The variant lines differ with respect to the following features:
Table 2: Differences between the variant lines
Feature RFU63x-131xx RFU63x-041xx
Internal antenna Yes No
Number of connections for
external antennas
3 x female connector, TNC
reverse
4 x female connector, TNC
reverse
Housing dimensions 238.6 mm x 238.6 mm x
64.3 mm
239 mm x 197 mm x 40.1 mm
Within the same variant line, the device types differ with respect to the following region-
related, non-modifiable features:
Radio equipment approval
Carrier frequency range
Maximum transmitting power of the internal antenna (RFU63x-131xx only) and the
external antennas
RFU65x
The RFU65x product family consists of one variant line:
3 PRODUCT DESCRIPTION
16
O P E R A T I N G I N S T R U C T I O N S | RFU63x, RFU65x 8014335/ZTL9/2018-10-14 | SICK
Subject to change without notice