Figure 8: The optimal orientation of the transponder for good writing and reading results is
demonstrated here for an external UHF antenna
Mounting and aligning the device
NOTICE
Avoid mutual interference when operating several devices
When the reading ranges of several independently operated devices overlap, this can
lead to mutual impairment of the system performance of the devices.
To avoid these situations, each of the devices support a SyncMode feature.
SyncMode enables several devices connected to the same Ethernet network to synchro‐
nize their reading responses. SyncMode ensures that only one device at a time is per‐
forming a read operation and therefore communicating over the air interface.
SyncMode is available for all devices in the RFU6xx product family that have an Ether‐
net interface.
SyncMode is not supported for RFU62x-104xx devices (serial variant).
1. Prepare the base for mounting the bracket of the device, see "Preparation for
mounting", page 27.
Recommendation: Depending on the application it may be possible to use one of
the optional SICK brackets. If necessary, perhaps also in combination with other
SICK brackets.
2. At the intended reading location, place an object with transponder within the work‐
ing range of the device (static object only).
3. Mount the device bracket onto the base.
4. Tighten screws through the bracket into the blind tapped holes of the device and
slightly tighten.
5. Orient the front side of the device towards the object.
5 MOUNTING
32
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK