"Ethernet" (Host 2)
Input 2 3
Input 1 4
Output 1 2
Output 2 1
RFU62x-101xx
Connection
module
"Power/Serial Data/CAN/I/O"
(Aux 1, Host 1)
...
...
1
2
V
S
GND
HOST
V
S
EthernetEthernet
Further data
processing
Cable à Cable ß
Reading result 8
"Serial RS-232/RS-422/485" (Host 1) 9
7
5
6
Figure 14: Read mode: Block diagram for the RFU62x-101xx with optional connection module
1
Digital switching output 2, for example for connecting an LED
2
Digital switching output 1, for example for connecting an LED
3
Digital switching input 2, for example for connecting an incremental encoder
4
Digital switching input 1, for example for connecting a read cycle trigger sensor
5
Supply voltage V
S
(V
S
= U
V
)
6
Connection module CDB620, CDB650-204 or CDM420
7
Data further processing
8
Read result (configurable output format 1 or 2)
9
Alternative to Ethernet host port
ß
Adapter cable (male connector, M12, 4-pin, D-coded/male connector, RJ-45, 8-pin)
à
For CDB620 and CDM420: Adapter cable (female connector, M12, 17-pin, A-
coded / male connector, D-Sub-HD, 15-pin)
For CDB650-204: Connection cable 1:1 (female connector, M12, 17-pin, A-coded/male
connector, M12, 17-pin, A-coded)
NOTE
Two additional external digital inputs and outputs respectively are optionally available
for the device. This requires the CMC600 parameter cloning module, which is built into
the CDB or CDM connection module.
These modules can be supplied as optional accessories.
For details of the characteristics of the external switching inputs and outputs, see
"Wiring the digital switching inputs (RFU62x-101xx/RFU62x-104xx)", page 61 and see
"Wiring the digital switching outputs (RFU62x-101xx/RFU62x-104xx)", page 63.
6
ELECTRICAL INSTALLATION
40
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice