Table 29: Signal assignment of adapter cable with open end
Pin Signal Function Wire color
1 GND Ground Blue
2 V
S
Supply voltage Brown
3 CAN L CAN bus (IN/OUT) Green
4 CAN H CAN bus (IN/OUT) White
5 TD+ (RS-422/485), host Host interface (sender+) Pink
6 TD– (RS-422/485), host
TxD (RS-232), host
Host interface (sender-) Yellow
7 TxD (RS-232), Aux Aux interface (sender) Black
8 RxD (RS-232), AUX Aux interface (receiver+) Gray
9 SensGND Sensor 1 switching input ground Gray-brown
10 Sensor 1 Digital switching input 1 Violet
11 RD+ (RS-422/485), host Host interface (receiver) Gray-pink
12 RD– (RS-422/485), host
RxD (RS-232), host
Host interface (receiver–) Red-blue
13 Result 1 Digital switching output 1 White-green
14 Result 2 Digital switching output 2 Brown-green
15 Sensor 2 Digital switching input 2 White-yellow
16 N. c. – Yellow-brown
17 N. c. – White-gray
14.4.3 “Power/SerialData/CAN/I/O” connection to customer-specific connection equipment or control
cabinet
Adapter cable, Ecolab
Part no. 2081094 (2 m), shielded, Ecolab, suitable for 2 A
For RFU62x-101xx (Ethernet variant)
Ambient temperature range:
For mobile installation: –25 °C to +80 °C, for fixed installation: –40 °C to +80 °C
...
ð
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
1 2
Figure 38: Adapter cable, e.g. part no. 2081094 (2 m)
1
Female connector, M12, 17-pin, A-coded (view from front)
2
Illustration may differ
Table 30: Signal assignment of adapter cable with open end
Pin Signal Function Wire color
1 GND Ground Blue
2 V
S
Supply voltage Brown
3 CAN L CAN bus (IN/OUT) Green
4 CAN H CAN bus (IN/OUT) White
14 ANNEX
90
O P E R A T I N G I N S T R U C T I O N S | RFU62x 8015930/ZTM0/2018-11-06 | SICK
Subject to change without notice