10 Technical data
10.1 Features
Attribute Value
Tasks Positioning, inspection, measurement
Technology 3D, line scan, image analysis
Working distance (measured from front win‐
dow)
1008: 56...116 mm range
1030: 141...541 mm range
1060: 291...1091 mm range
Width at minimum working distance 1008: 40 mm
1030: 90 mm
1060: 180 mm
Width at maximum working distance 1008: 75 mm
1030: 330 mm
1060: 660 mm
Maximum height range 1008: 60 mm
1030: 400 mm
1060: 800 mm
Light source Visible red light (laser, 660 nm)
Laser class 2 (EN/IEC 60825-1:2014)
2M (EN/IEC 60825-1:2007)
Complies with 21 CFR 1040.10 except for
deviations pursuant to Laser Notice No. 50,
dated June 24, 2007
Laser fan angle 45°±2°
Imaging angle 1008/1030: 65°
1060: 67°
Offline support Emulator
Toolset Angle, Area, Blob, Distance, Edge, Fix Plane,
Plane, Peak, Point, Shape
10.2 Ambient data
Attribute Value
Shock load 15 g / 6 ms (EN 60068-2-27)
Vibration load 5 g, 10 Hz...150 Hz (EN 60068-2-6)
Ambient operating temperature 0 °C ... +40 °C (adequate heat dissipation is
required, see "Mounting instructions", page 16)
Ambient storage temperature –20 °C ... +70 °C
Permissable relative air humidity 0% ... 90%, non-condensing
10.3 Interfaces
Attribute Value
Operator interface SOPAS
Configuration software SOPAS
Communication interfaces Gigabit Ethernet (TCP/IP), serial (RS-232), con‐
figurable digital I/O
Digital inputs 3 x, non-isolated
TECHNICAL DATA 10
8021808/12ID/2019-01 | SICK O P E R A T I N G I N S T R U C T I O N S | TriSpector1000
61
Subject to change without notice