7.5.5 Recording images
Use the Image recording button ( ) to save 3D images to disk. The saved images can be
used in the emulator to configure tools offline. See "Using the SOPAS ET emulator",
page 54 for information on how to use the emulator.
The saved images are Portable Network Graphics (.png) files which contain both range
data and reflectance data. Each file name includes the name of the active job, the
image number and the overall image decision.
To save images to disk:
1. Click the Image recording button.
The Image recording settings window opens, and the Image recording button turns
black.
2. Select a destination folder.
3. Select the Max number of images checkbox to specify the maximum number of
images to save.
4. Select the Reset image numbering checkbox to overwrite existing files in the destina‐
tion folder.
5. Click the Start button.
The image recording starts. An image is saved each time a scan is made.
6. Click the Image recording button stop the image recording. If the Max number of images
checkbox was selected, the recording will stop automatically when the specified
number of images have been saved.
7.6 Task workflow step
7.6.1 Using the tools
1. After the image configuration has been done in the Image workflow step, select
the Task workflow step.
The image is shown in the Live 3D view.
2. Click the Save Job Image button.
The Tools buttons appear and the image view changes to Job.
3. Click on a tool button to apply the tool to the image. You can apply multiple tools to
the image, but only one Shape tool.
4. Click the eye symbol ( ) in the parameter pane to toggle the visual representa‐
tion on or off. If applicable, click one more time to also show the tool's region of
interest.
Selecting a tool in the parameter pane will always show the visual representation
for the tool.
The Job image view shows the saved job image. Tools can only be applied in this view.
The Live 3D view shows the latest scanned image.
For an example of how to use tools for image analysis, see "Application example: Count‐
ing chocolates", page 41.