EasyManua.ls Logo

SICK TriSpector1000

SICK TriSpector1000
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Attribute Value
Digital in-/ outputs 4 x, non-isolated, configurable
Encoder interface RS-422/TTL (DBS36E-BBCP02048)
Maximum encoder frequency 300 kHz
Fieldbuses Ethernet/IP via Gigabit Ethernet port
ProfiNet via serial interface connected to SICK
module CDF600-2200
10.4 Mechanics and electronics
Attribute Value
Power I/O M12 male connector, 12-pin A-coded
Gigabit Ethernet M12 female connector, 8-pin X-coded
Encoder M12 female connector, 8-pin A-coded
Connector material Brass, nickel-plated
Supply voltage 24 V DC, ± 20 %
SELV + LPS according to EN 60950-
1:2014-08 or Class 2 according to
UL1310 (6th edition)
Supply current 1.5 A maximum; external fuse required
Power consumption 11 W maximum
Ripple < 5 Vpp
Current consumption 400 mA with no output loads
Enclosure rating IP 67
Safety EN 60950-1:2014-08
Protection class III
EMC Immunity: EN 61000-6-2:2005
Emission: EN 61000-6-3:2007
Weight (not including cables) 1008: 900 g
1030: 1300 g
1060: 1700 g
Dimensions (L x W x H) 1008: 136 mm x 62 mm x 84 mm
1030: 217 mm x 62 mm x 84 mm
1060: 307 mm x 62 mm x 84 mm
Optics Fixed
10.5 Input switching levels
Attribute Value
Input levels Up to 30 V
Stresses beyond this over-voltage level can
cause permanent damage to the device.
Input threshold levels High: > 15.0 V
Low: < 5.0 V
Hysteresis > 1.0 V
Input current High: < 3.0 mA
Low: < 0.1 mA
10 TECHNICAL DATA
62
O P E R A T I N G I N S T R U C T I O N S | TriSpector1000 8021808/12ID/2019-01 | SICK
Subject to change without notice

Table of Contents

Related product manuals