Saving a configuration
NOTICE
If a configuration is not saved before disconnecting the power to the device, all settings
will be lost.
Select Save permanent from the Parameter menu in the SOPAS ET functions panel to save
a configuration from the device's working memory to the flash memory. If the device
has a microSD memory card inserted, the configuration is saved to both the flash mem‐
ory and the microSD memory card.
Cloning a device using a microSD memory card
Follow the steps below to clone a device, which means copying the configuration and IP
address from one device to another. The instruction requires that the first device has a
microSD card inserted and is connected to SOPAS ET.
1. In SOPAS ET, select Save permanent from the Parameter menu to save the current
configuration to the microSD memory card.
2. Move the microSD memory card from the first to the second device.
3. Power on the second device.
The configuration on the microSD memory card is loaded into the working memory
of the second device.
4. Select Save permanent from the Parameter menu in the SOPAS ET functions panel to
save the configuration to the device's flash memory.
7.4 Workflow steps
To configure the TriSpector1000, click the workflow steps in the user interface (see
figure 19). It is possible to change workflow step at any time during the configuration.
Figure 19: Workflow steps
Image
The Image workflow step is used to set up image acquisition for good image quality. Two
different views are available: Live 3D and Sensor. See "Image workflow step", page 29
for more information.
Task
The Task workflow step contains tools for image analysis. Two different views are avail‐
able: Live 3D and Job. The Job image is the reference image where the tools are applied
and the tool configuration is done. See "Task workflow step", page 32 for more infor‐
mation.
Results
The Results workflow step contains settings for result processing and output handling.
Note that a bold red underscore in the input fields indicates syntax error. See "Results
workflow step", page 43 for more information.
Interfaces
The Interfaces workflow step contains settings for connections to external interfaces.
See"Interfaces workflow step", page 50 for more information.