Table 14: General system data
Minimum Typical Maximum
Weight (without packaging) – 0.18 kg –
Electrical Safety Class III
Immunity to interference EN 61000-6-2
Emitted interference EN 61000-6-4
Table 15: Operating data
Minimum Typical Maximum
Ambient operating temperature
(UL/C
SA: ambient temperature)
–25 °C – 55 °C
Storage temperature –25 °C – +70 °C
Air humidity 10% to 95%, non-condensing
Climatic conditions EN 61131-2
Table 16: Mechanical strength
Minimum Typical Maximum
Vibration EN 61131-2
Vibration resistance 5–500 Hz/5 grms (EN 60068-2-64)
Table 17: Terminal and connection data
Minimum Typical Maximum
Single-wire or fine-stranded 1 × 0.14 mm² to 2.5 mm² or
2 × 0.14 mm² t
o 0.75 mm²
Fine-stranded with ferrule in accor‐
d
ance with EN 46288 (1x)
1 × 0.25 mm² to 2.5 mm² or
2 × 0.25 mm² to 0.5 mm²
Stripping length – – 8 mm
Maximum tightening torque – – 0.6 Nm
For UL-508 and CSA applications
UE410-SD3xx
Connection cross-section AWG 30–12 (use only 60/75 °C copper wire)
Tightening torque
5–7 lb•in
UE410-SD4xx
Connection cross-section AWG 30–12 (use only 60/75 °C copper wire)
TECHNICAL DATA 13
8021417/2018-01-17 | SICK O P E R A T I N G I N S T R U C T I O N S | UE410 Safeguard Detector Box
41
Subject to change without notice