WLL180T Photoelectric sensors for fiber-optic cables
2010-08-02 SICK 23
Subject to change without notice
2. Operating mode Configuring
active
4. In the basic menu, select
Expert mode by pressing the
arrow keys.
5. Expert mode is shown on the
display
6. Press Mode key
7. In Expert mode, select Master
teach-in by pressing the arrow
keys
8. Master teach-in setting is
shown on the display
+
+
9. Select between “no” and
“YES” by pressing the arrow
keys
3.8 Master Teach-in (Bus operation only)
+
Teaching of all connected extension units (only available in
bus mode):
no: Does not perform teach-in,
YES: Performs teach-in for all connected extension units (see
page 6) according to the set teach-in mode.
Note:
Locked (LocL) extension units are not taught.
3. Press Mode key
1. Press Mode key for 2 s
10. Close Expert mode with arrow
key
+
11. Finish selection with Mode key
12. Select ending the adjustment
(End)
13. Finish selection with Mode key
+