Availability, mobility, and controller functionality
A31003-W1040-U101-1-7619, July 2006 DRAFT
206 HiPath Wireless Controller, Access Points and Convergence Software V4.0, C10/C100/C1000 User Guide
hwc_controlleravailmobility.fm
Configuring Check Point event logging
To enable and configure Check Point:
1. From the main menu, click Wireless Controller Configuration. The Wireless Controller
Configuration screen appears.
2. In the left pane, click Check Point. The Check Point Configuration screen appears.
3. To enable check point logging, select the Enable Check Point Logging checkbox.
4. Type the following information:
Check Point Server IP – Specifies the IP address of the ELA Management Station
ELA Port – Specifies the port to use for ELA. The default port is 18187.
>
Before you set up the HiPath Wireless Controller, you must first create OPSEC
objects for HiPath Wireless Controller in the Check Point management software. The
name and password you define must also be entered into the HiPath Wireless
Controller Check Point configuration screen.