Diagnostics and maintenance
5.6 SNMP
IE/PB LINK PN IO
76 Operating Instructions, 11/2017, C79000-G8976-C393-02
MRP Monitoring
Siemens Automation MIB
Note that write access is permitted only for the following MIB objects of the "System"
group:
sysContact
sysLocation
sysName
A set sysName is sent as the host name using DHCP option 12 to the DHCP server to
register with a DNS server.
For all other MIB objects and groups, only read access is possible for security reasons.
Access permissions using community name
The LINK uses the following community names to control the access rights in the SNMP
agent:
Table 5- 1 Access rights in the SNMP agent
Type of access
Community name
*)
Read access
public
Read and write access
private
*) Note the use of lowercase letters!