Page 4 MultiRanger 100/200 – INSTRUCTION MANUAL 7ML19981FB05
mmmmm
Specifications
Range
0.3 m (1 ft) to 15 m (50 ft), dependent on transducer
Accuracy
0.25% of maximum range or 6 mm (0.24”), whichever is greater
Resolution
0.1% of program range
1
or 2 mm (0.08”), whichever is greater
Memory
1 MB static RAM with battery backup
512 kB flash EPROM
Programming
Primary
handheld programmer
Secondary
PC running SIMATIC PDM
PC running Dolphin Plus software
Display
back lit LCD
Temperature Compensation
Range: -50 to 150 °C (-58 to 302 °F)
Source
integral transducer sensor
TS-3 temperature sensor
programmable fixed temperature
Temperature Error
Sensor
0.09 % of range
1.
Program range is defined as the empty distance from the face of the transducer
(P006) plus any range extension (P801).