Configuring with Web Based Management
5.4 "Information" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
124 Configuration Manual, 03/2015, C79000-G8976-C267-08
The Rx Errors table has the following columns:
Interface
Shows the WLAN interface to which the entries apply.
Error types
The other columns after the WLAN interface contain the absolute numbers of the frames
received according to their error type.
The columns of the table distinguish the following error types:
Received Errors
Shows the number of bad frames that were received.
Duplicate Frames
Shows the number of frames that were received twice.
Decryption Errors
Shows the number of bad encrypted frames.
FCS Errors
Shows the number of frames in which the checksum was incorrect.
"Reset Counter" button
Click this button to reset the counters.