Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
179
5.5.11.4
v3 Users
User-specific security settings
On the WBM page, you can create new SNMPv3 users and modify or delete existing users.
The user-based security model works with the concept of the user name; in other words, a
user ID is added to every frame. This user name and the applicable security settings are
checked by both the sender and recipient.
Description
The page contains the following boxes:
User Name
Enter a freely selectable user name. After you have entered the data, you can no longer
modify the name.
The table has the following columns:
Select
Select the row you want to delete.
User Name
Shows the created users.
Group Name
Select the group to which the user will be assigned.
Authentication Protocol
Specify the authentication protocol. Can only be enabled, if this group supports the
function.
The following settings are available:
none
MD5
SHA

Table of Contents