Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
163
Severity Filter
Setting the severity filter
On this page, set the threshold levels for sending system event notifications.
The first table column shows the client type for which you are making the settings:
●
Sending system event messages by e-mail
●
Entry of system events in the log table
●
Entry of system events in the Syslog file
Select the required level from the drop-down lists of the second table column.
You can select from the following values:
●
System events are processed as of the severity level "Critical".
●
System events are processed as of the severity level "Warning".
●
System events are processed as of the severity level "Info".
Follow the steps below to configure the required level:
1. Select the required values from the drop-down lists of the second table column after the
client types.
2. Click the "Set Values" button.