Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
162 Configuration Manual, 03/2015, C79000-G8976-C267-08
Trap
The device sends an SNMP trap. This is only possible if "System > Configuration"
SNMPv1 Traps" is enabled.
Log Table
The device writes an entry in the event log table.
Syslog
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog client" function is enabled.
Fault
The device triggers a fault. The error LED lights up.
Procedure
Follow the steps below to change entries:
1. Select the check box in the row of the required event. Select the event in the column
under the following actions:
E-mail
Trap
Log table
Syslog
Fault
2. Click the "Set Values" button.