Configuring with Web Based Management
5.4 "Information" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
99
5.4.6
Faults
Error status
This page displays any errors that occur. Errors of the "Cold/Warm Start" event can be
deleted following confirmation.
If there are no more unanswered error/fault messages, the fault LED goes off.
The time calculation always begins after the last system start. When the system is restarted,
a new entry with the type of restart is created in the fault memory.
Description
The page contains the following boxes:
No. of Signaled Faults
Indicates how often the fault LED lit up and not how many faults occurred.
"Reset Counters" button
The number is reset with this button.
The table contains the following columns:
Fault Time
Shows the time the device has been running since the last restart when the described
fault occurred.
Fault Description
Display of the fault status for the device.
Clear Fault State
To delete errors of the "Cold/Warm Start" event, click the Clear Fault State" button.