Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
200 Configuration Manual, 03/2015, C79000-G8976-C267-08
5.5.15.2
Link Change
Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a status
change on a network connection.
If connection monitoring is enabled, an error is signaled
when there should be a link on a port and this is missing.
or when there should not be a link on a port and a link is detected.
A fault causes the signaling contact to trigger and the fault LED on the device to light up and,
depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log
table.
Description
The table has the following columns:
Port
Shows the available ports.
Setting
Select the setting from the drop-down list. You have the following options:
Up
Error handling is triggered when the port changes to the active status.
(From "Link down" to "Link up")
Down
Error handling is triggered when the port changes to the inactive status.
(From "Link up" to "Link down")
"-" (disabled)
The error handling is not triggered.
Procedure
1. From the relevant drop-down list, select the options of the slots / ports whose connection
status you want to monitor.
2. Click the "Set Values" button.