Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
172 Configuration Manual, 03/2015, C79000-G8976-C267-08
5.5.10.4
Static Leases
On this page you specify that devices with a certain MAC address are assigned to the
selected IPv4 address.
Description
The page contains the following boxes:
"Pool ID" drop-down list
Select the required IPv4 address band.
"Hardware Type" drop-down list
Ethernet MAC
Identification is based on the MAC address. Enter the MAC address in "Value". A MAC
address consists of six byes separated by hyphens in hexadecimal notation, e.g. 00-ab-
1d-df-b4-1d.
"Value" input box
Enter the MAC address and click the "Create" button to create the entry.
Note
A maximum of 20 entries are possible.
The table has the following columns:
Select
Select the check box in the row to be deleted.
Pool ID
Shows the number of the IPv4 address band.
Note
Only Pool ID = 1 is supported.
HW Type
Shows that the IPv4 address depends on the MAC address.