Configuring with Web Based Management
5.5 "System" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
207
Information about the license of the KEY-PLUG
A C-PLUG can only store the configuration of a device. In addition to the configuration, a
KEY-PLUG also contains a license that enables certain functions of your SIMATIC NET
device.
Description of the displayed boxes
State
Shows the status of the KEY-PLUG. The following are possible:
ACCEPTED
The KEY-PLUG in the device contains a suitable and valid license.
NOT ACCEPTED
The license of the inserted KEY-PLUG is not valid.
NOT PRESENT
No KEY-PLUG is inserted in the device.
MISSING
There is no KEY-PLUG or a C-PLUG with the status "FACTORY" inserted in the
device. Functions are configured on the device for which a license is required.
WRONG
The inserted KEY-PLUG is not suitable for the device.
UNKNOWN
Unknown content of the KEY-PLUG.
DEFECTIVE
The content of the KEY-PLUG contains errors.
Order ID
Shows the order number of the KEY-PLUG. The KEY-PLUG is available for various
functional enhancements and for various target systems.