EasyManua.ls Logo

Siemens SCALANCE W780

Siemens SCALANCE W780
317 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring with Web Based Management
5.6 "Interfaces" menu
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
243
CSV file
The CSV file contains information on the configuration of the device and detailed information
on all individual measurements and is divided into two areas. The first area contains the
configured settings:
The system name of the client
The IP address of the device
The MAC address of the device
The total number of measured values
The interval between acquisition of two measured values
The maximum data rate
The setting of the external antennas
The maximum possible transmit power
The second area is a table. The table contains the following for each measured value:
Sample
The consecutive number of the measurement
Timestamp
The time stamp
BSSID
The BSSID
Signal
The received signal strength in %
dBm
The received signal strength in dBm
RSSI
The raw value of the RSSI (Received Signal Strength Indication)
Roaming
The roaming indicator. The indicator changes between 0 and 1 with each roam
Channel
The current channel or the channel on which the client is connected to the access point
HT-40
The channel bandwidth 40 MHz
Avg. TX-Rate
The average data rate of the sent data packets
AP System Name
The name of the access point