Technical basics
3.3 iPCF / iPCF-MC
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 03/2015, C79000-G8976-C267-08
41
Restrictions
iPCF and iPCF-MC are developments of Siemens AG and function only with nodes on
which iPCF / iPCF-MC is implemented.
With an access point with several WLAN interfaces, it is possible to use both iPCF as well
as standard WLAN at the same time.
Access points with a WLAN interface cannot take part in the iPCF-MC procedures, iPCF
is, however, possible.
Requirements for iPCF-MC
iPCF-MC uses the two wireless interface of the access point in different ways: One interface
works as the management interface and sends a beacon every five milliseconds. The other
interface transfers the user data.
The following requirements must be met before you can use iPCF-MC:
Only devices with two WLAN interfaces can be used as access points
The data interface (WLAN1) and management interface (WLAN2) must be operated in
the same frequency band and must match in terms of their wireless coverage. iPCF-MC
will not work if the two wireless interfaces are equipped with directional antennas that
cover different areas.
The management interfaces of all access points to which a client can change must use
the same channel. A client scans only this one channel to find accessible access points.
Transmission based on IEEE 802.11h (DFS) cannot be used for the management
interface. 802.11h (DFS) is possible for the data interface.
A client must support this feature on its WLAN interface.