Syslog messages
C.2 Syslog messages
SIMATIC CC7
Operating Instructions, 10/2019, C79000-G8976-C503-02
143
The output messages can contain the following tags:
Tag
Description
Format
Possible values or exam-
ple
{IP address} IPv4 address according to RFC1035
IPv6 address according to RFC4291 Section 2.2
%d.%d.%d.%d
XXX.XXX.XXX.XXX
192.168.1.105
2001:DB8::8:800:200C:41
7A
{FQHN} Fully Qualified Host Name: Completely specified host
name; specification as domain (FQDN) or as IP ad-
dress.
FQDN: host1.com
IPv4: %d.%d.%d.%d
server1
192.168.1.105
{Protocol}
Layer 4 protocol or service used that generated the
event.
%s UDP | TCP | WBM | Telnet
| SSH | Console | PNIO |
PB | OPC | TFTP | SFTP
{User name} String (without spaces) that identifies the authenticat-
ed user by his or her name.
%s <Name>
{Local inter-
face}
Symbolic name of the local interface %s Console
{Time mi-
nute}
{Timeout}
Number of minutes %d 44
{Time sec-
ond}
Number of seconds %d 44
{Failed login
count}
Number of failed login attempts %d 10
{Max ses-
sions}
Maximum number of sessions %d 10
{Version}
Name of the version (without spaces)
%s
V1.0.3SP1
{Config de-
tail}
String (with spaces) for the identification of a part of
the configuration
%s OpenVPN
C.2 Syslog messages
The gateway outputs the following SYSLOG messages, sorted by classes:
C.2.1 Process communication status
SE_COMMUNICATION_STARTED_(protocol)
Message text
{Protocol}: User {User name} started the process communication.
Example
Console: User <user name> started the process communication.
Explanation
The user has started the process communication.
Severity
Notice
Facility
local0
Standard
-