Application and functions
1.5 Configuration limits - communication
SIMATIC CC7
18 Operating Instructions, 10/2019, C79000-G8976-C503-02
1.5 Configuration limits - communication
The gateway supports the following maximum quantity structure.
Connection resources over the process interface
Number of connections to S7 stations
CC712: Max. 1 S7 connection to one S7 connection
CC716: Max. 7 S7 connections with S7 stations (1 connection per S7 station)
Number of connections to Modbus stations
Max. 10 connections to Modbus stations
Number of connections to the configuration PC
Max. 1 HTTPS connection
Number of process data
Tags in the data area of S7 CPUs
CC712: Max. 500 tags in total
CC716: Max. 3500 tags in total
Tags per S7 CPU
Max. 500 tags
Tags per array (import from S7 CPU)
Max. 500 tags
Tags in the data area of Modbus stations
Max. 100 tags per Modbus station
Connections over the Cloud interface
Number of sessions with the broker
Max. 1 session
Number of connections to OPC UA clients
Max. 10 simultaneous sessions with OPC UA clients
OPC UA server
As OPC UA server, the gateway supports the following quantity structure.
Number of tags in the CPU data area
CC712: Total of max. 500 symbols / PLC tags
CC716: Total of max. 3500 symbols / PLC tags