Syslog messages
C.2 Syslog messages
SIMATIC CC7
146 Operating Instructions, 10/2019, C79000-G8976-C503-02
C.2.5 Remote session termination
SE_RAS_SESSION_TERMINATED_INACTIVITY_(protocol)
Message text {Protocol}: Remote session {Config detail} was closed after {Time second} seconds of inactivity.
WBM: Remote session o1cs3jjKy... was closed after 600 seconds of inactivity.
The session was closed after a period of inactivity.
IEC 62443-3-3 Reference: SR 2.6
C.2.6 Concurrent session control
SE_ACCESS_DENIED_NUMBER_OF_CONCURRENT_SESS_(protocol)
{Protocol}: The maximum number of {Max sessions} concurrent login session exceeded.
WBM: The maximum number of 1 concurrent login sessions exceeded.
The maximum number of simultaneous sessions has been reached.
IEC 62443-3-3 Reference: SR 2.7
C.2.7 Non-repudiation (config change)
SE_CONFIG_CHANGE_(protocol)_(complete configuration)
{Protocol}: User {User name} has changed configuration.
WBM: User admin has changed configuration.
User has changed the configuration data by loading a new *.cfg file.
IEC 62443-3-3 Reference: SR 2.12
SE_CONFIG_CHANGE_(protocol)_(reset to factory)
{Protocol}: User {User name} has initiated a reset to factory defaults.
WBM: User admin has initiated a reset to factory defaults.
User has initiated a reset to factory settings.
Facility local0
IEC 62443-3-3 Reference: SR 2.12