Configuration
4.6 Interface configuration
SIMATIC CC7
Operating Instructions, 10/2019, C79000-G8976-C503-02
57
Table 4- 2 Preset address data
Address data preset in the factory
Process interface / Cloud interface
Note
No address check / configuration rules
The address bands are not checked automatically.
Make sure that the subnets of the two interfaces are not the same.
Configuration of the local I
P addresses of the gateway is not permissible.
For the IPv6 address, configuration of multicast and broadcast addresses is not permissible.
You configure both interfaces separately.
●
Cloud interface in the same subnet
You can find this option under the parameter group of the Cloud interface.
Only enable the option if the connection to the cloud is in the same subnet as the process
connection.
When the option is enabled, the Cloud interface is disabled and the corresponding input
fields are locked.
The following parameters apply to both interfaces.
●
MAC address
MAC address of the interface
●
IPv4 / IPv6
Enable the respective IP address.
Alternatively, the Cloud interface supports IPv6 addresses.
Note
No reachability when IP address data of the process interface is applied
The IP parameters of t
he process interface must match the settings of the IP address